Middle East Supply DeskProject specifications · Export documentation · Responsive quotationellen@waterproofingbest.com
All products / EXCALD TPO

Waterproofing membranes

EXCALD TPO — Fibre-Backed TPO Roofing Membrane

Thermoplastic polyolefin roofing membrane with integrated polyester fabric backing and hot-air-welded seams. Designed for exposed roof assemblies where UV resistance, dimensional stability and seam quality are central to system selection.

EXCALD TPO Fibre-Backed TPO Roofing Membrane

Product image

Recommended applications

Commercial and industrial exposed roofs, new roofing and refurbishment.

Key product data

Membrane thickness1.2 / 1.5 / 1.8 mm
Roll dimensions2.0 × 20 m or 1.2 × 20 m
ColourWhite / Grey
StorageBelow 38°C
1.2 mm roll weight2 × 20 m: 61 kg; 1.2 × 20 m: 38 kg
1.5 mm roll weight2 × 20 m: 74 kg; 1.2 × 20 m: 46 kg
1.8 mm roll weight2 × 20 m: 88 kg; 1.2 × 20 m: 55 kg

Reference information from the supplied product data. Performance and consumption depend on the grade and application conditions; confirm details in the batch documentation.

Standards & test methods

Reference standards and test methods stated in the product technical data. * The last two grade headings are missing from the supplied physical-properties table. Columns B/C preserve their original order without assigning a thickness. Factory-seam units and conversions are reproduced as printed and require confirmation. “typ.” means typical.

Property / conditionASTM D6878 requirement1.2 mm–RFTDS column B*TDS column C*
Nominal thickness tolerance (%); ASTM D751±15±10±10±10
Thickness over scrim, in (mm); ASTM D6878 optical method, average of 3 areas≥0.012 (0.305)0.018 (0.457) typ.0.024 (0.610) typ.0.032 (0.813) typ.
Breaking strength; ASTM D751 grab method≥220 lbf (976 N)≥225 lbf (1.0 kN); 250 lbf (1.2 kN) typ.≥250 lbf (1.1 kN); 290 lbf (1.3 kN) typ.≥270 lbf (1.2 kN); 350 lbf (1.55 kN) typ.
Reinforcement elongation at break (%); ASTM D751 grab method≥15≥15; 25 typ.≥15; 25 typ.≥15; 25 typ.
Tearing strength, lbf (N); ASTM D751 procedure B, 8 × 8 in≥55 (245)≥55 (245); 130 (578) typ.≥55 (245); 130 (578) typ.≥55 (245); 130 (578) typ.
Brittleness point; ASTM D2137≤-40°F (-40°C)≤-40°F (-40°C)≤-40°F (-40°C)≤-40°F (-40°C)
Linear dimensional change (%); ASTM D1204, 6 h at 158°F±1±1±1±1
Water absorption (% mass); ASTM D471, top surface, 166 h in water at 158°F≤3.0≤3.0; 2.0 typ.≤3.0; 2.0 typ.≤3.0; 2.0 typ.
Factory seam strength, lbf/in (kN/m), as printed; ASTM D751 grab method≥66 (290)*≥66 (290)*≥66 (290)*≥66 (290)*
Water vapour permeance (perms); ASTM E96 procedure BNo requirement≤0.10; 0.05 typ.≤0.10; 0.05 typ.≤0.10; 0.05 typ.
Puncture resistance, lbf (kN); FTM 101c method 2031No requirement≥250 (1.2); 325 (1.4) typ.≥250 (1.2); 325 (1.4) typ.≥250 (1.2); 325 (1.4) typ.
After heat ageing; ASTM D573, 670 h at 240°FNo requirementPassPassPass
Typical weight (kg/m²)No requirement1.21.61.9

References reproduce the editions listed in the product data. Confirm the required edition, selected grade and supporting test report for consultant approval.

Application & selection notes

Confirm the roof build-up, attachment method, wind-uplift design and compatible accessories with the project consultant. Hot-air weld seams and verify weld quality. Membrane thickness and total composite construction must be clearly identified in the RFQ.

For hot, dry site conditions, check substrate temperature, moisture, working time and curing before application. The heat resistance of a cured membrane does not permit installation outside the application limits in its TDS.

Specify for Saudi Arabia, UAE & GCC projects

Send the project location or destination port, application, substrate, required thickness, area in m², quantity and delivery schedule. Request the selected grade, export packing, TDS and batch documentation for consultant review. Manufactured in China; project approvals are reviewed for each enquiry.

Contact the export team