Exterior concrete or rendered walls and façade maintenance.

Key product data

Set70 kg: 20 kg liquid + 2 × 25 kg powder
Liquid:powder1:2.5
Reference consumption at 1 mm≈2.0 kg/m²
Application temperature5–35°C

Reference information from the supplied product data. Performance and consumption depend on the grade and application conditions; confirm details in the batch documentation.

Standards & test methods

Reference standards and test methods stated in the product technical data.

Property / conditionTechnical requirement / reference value
TDS standard referenceQ/0783WHY061-2025
Solids content≥70%
Impermeability: 0.3 MPa, 30 minNo leakage
Tensile strength: untreated≥1.8 MPa
Tensile-strength retention: heat treatment≥80%
Tensile-strength retention: alkali treatment≥70%
Tensile-strength retention: water immersion≥70%
Elongation: untreated≥30%
Elongation: heat treatment≥20%
Elongation: alkali treatment≥20%
Elongation: water immersion≥20%
Bond strength: untreated≥1.0 MPa
Bond strength: wet substrate≥1.0 MPa
Bond strength: alkali treatment≥1.0 MPa
Bond strength: water immersion≥1.0 MPa
Negative-side mortar impermeability≥0.8 MPa
Water vapour transmission≥50 g/(m²·24 h)

References reproduce the editions listed in the product data. Confirm the required edition, selected grade and supporting test report for consultant approval.

Application & selection notes

Apply to a sound, damp substrate without standing water. Use the mixed coating within two hours, do not dilute with water and protect against rain for the first 24 hours. Check compatibility with the façade finish.

For hot, dry site conditions, check substrate temperature, moisture, working time and curing before application. The heat resistance of a cured membrane does not permit installation outside the application limits in its TDS.

Specify for Saudi Arabia, UAE & GCC projects

Send the project location or destination port, application, substrate, required thickness, area in m², quantity and delivery schedule. Request the selected grade, export packing, TDS and batch documentation for consultant review. Manufactured in China; project approvals are reviewed for each enquiry.

Contact the export team