Middle East Supply DeskProject specifications · Export documentation · Responsive quotationellen@waterproofingbest.com
All products / EXCALD WELDED HDPE

Waterproofing membranes

EXCALD WELDED HDPE — Welded HDPE Pre-Applied Waterproofing Membrane

Pre-applied, concrete-bonded HDPE waterproofing with hot-welded laps. The welded joint system offers a separate installation option for below-ground works where the project specification calls for welded seams.

EXCALD WELDED HDPE Welded HDPE Pre-Applied Waterproofing Membrane

Product image

Recommended applications

Basement slabs and walls, tunnels and underground structures.

Key product data

Composite thickness1.2 / 1.5 / 1.8 / 2.0 mm
Roll dimensions1.2 × 20 m or 2.0 × 20 m
Lap100 mm per supplied method

Reference information from the supplied product data. Performance and consumption depend on the grade and application conditions; confirm details in the batch documentation.

Standards & test methods

Reference standards and test methods stated in the product technical data. Welded-joint peel values are reproduced as printed; confirm the test specimen dimensions and units with the test report.

Property1.2 mm1.5 mm1.8 mm2.0 mmTest method
Bare HDPE film thickness (mm)0.850.951.051.20ASTM D3767-2003
Tensile strength (MPa)21252528ASTM D412-2016
Elongation (%)500500500500ASTM D412-2016
Puncture resistance (N)800100012001350ASTM E154-2008
Peel adhesion to concrete (N/m)1800 ±3001800 ±3001800 ±3001800 ±300ASTM D903
Low-temperature flexibility≤-25°C≤-25°C≤-25°C≤-25°CASTM D1970
Dimensional change (%)≤1≤1≤1≤1ASTM D1204
ColourWhiteWhiteWhiteWhite
Composite membrane thickness (mm)1.21.51.82.0ASTM D3767-2003
Adhesive thickness (mm)0.2–0.30.2–0.30.2–0.30.2–0.3
Peel adhesion: welded joints (N), as printed in TDS11000150001500015000ASTM D6392:2012
Roll dimensions1.2 × 20 m / 2 × 20 m1.2 × 20 m / 2 × 20 m1.2 × 20 m / 2 × 20 m1.2 × 20 m / 2 × 20 m

References reproduce the editions listed in the product data. Confirm the required edition, selected grade and supporting test report for consultant approval.

Application & selection notes

Keep weld surfaces clean and dry; set welding temperature and speed by trial welds and site testing. Inspect laps, repairs and penetrations before concrete placement. Application temperature must be at least 5°C. Do not confuse welded-lap and adhesive-lap specifications.

For hot, dry site conditions, check substrate temperature, moisture, working time and curing before application. The heat resistance of a cured membrane does not permit installation outside the application limits in its TDS.

Specify for Saudi Arabia, UAE & GCC projects

Send the project location or destination port, application, substrate, required thickness, area in m², quantity and delivery schedule. Request the selected grade, export packing, TDS and batch documentation for consultant review. Manufactured in China; project approvals are reviewed for each enquiry.

Contact the export team