Middle East Supply DeskProject specifications · Export documentation · Responsive quotationellen@waterproofingbest.com
All products / BIOGO-NRC-T

Bituminous coatings

BIOGO-NRC-T — Special Non-Curing Rubberised Bitumen Waterproof Coating

Special hot-applied, non-curing rubberised bitumen for composite waterproofing. The supplied TDS includes a 90°C heat-resistance test, distinguishing NRC-T from the standard NRC grade.

BIOGO-NRC-T Special Non-Curing Rubberised Bitumen Waterproof Coating

Product image

Recommended applications

Protected roofs, below-ground structures, planted-roof systems and detailing.

Key product data

Pack20 kg
Solids≥98%
Heat resistance test90°C; no sliding, flowing or dripping

Reference information from the supplied product data. Performance and consumption depend on the grade and application conditions; confirm details in the batch documentation.

Standards & test methods

Reference standards and test methods stated in the product technical data.

Property / conditionTechnical requirement / reference value
TDS standard referenceT/CBMF 44-2019
Flash point≥180°C
Solids content≥98%
Adhesion: dry and damp substrates100% cohesive failure within the coating
Extensibility≥15 mm
Low-temperature flexibility-20°C; No cracking
Heat resistance90°C; No flowing, sliding or dripping
Self-healingNo leakage
Water migration at 0.6 MPaNo water migration
Heat ageing: 70°C, 168 h; extensibility / flexibility≥15 mm; -15°C, No cracking
Acid resistance: 2% H₂SO₄; appearance / extensibility / mass changeNo appearance change; ≥15 mm; ±2.0%
Alkali resistance: 0.1% NaOH + saturated Ca(OH)₂; appearance / extensibility / mass changeNo appearance change; ≥15 mm; ±2.0%
Salt resistance: 3% NaCl; appearance / extensibility / mass changeNo appearance change; ≥15 mm; ±2.0%
Oil bleeding≤2 filter-paper sheets
Stress relaxation: untreated and aged at 70°C for 168 h≤35%
Application reference: membrane slip resistanceNo sagging or slippage at 90°C
Application reference: tack retention≥60 min

References reproduce the editions listed in the product data. Confirm the required edition, selected grade and supporting test report for consultant approval.

Application & selection notes

Follow the controlled heating and application method in the TDS. Never exceed 200°C during heating. Provide trained operators and suitable membrane isolation. Do not interpret the heat test as unrestricted suitability for all hot-roof assemblies.

For hot, dry site conditions, check substrate temperature, moisture, working time and curing before application. The heat resistance of a cured membrane does not permit installation outside the application limits in its TDS.

Specify for Saudi Arabia, UAE & GCC projects

Send the project location or destination port, application, substrate, required thickness, area in m², quantity and delivery schedule. Request the selected grade, export packing, TDS and batch documentation for consultant review. Manufactured in China; project approvals are reviewed for each enquiry.

Contact the export team